Landing doors are something engineers pass through many times a day, which can make it easy to underestimate the risks they carry. When something goes wrong with a landing door during maintenance, the consequences can be severe, including falls into the shaft.
In this installment of our lift safety blog series, we look at the risks around landing doors on site, and what engineers should be doing to keep safe.
Understanding the risks
Landing doors sit at the boundary between the safety of the floor and the drop of the shaft, which is what makes them one of the higher-risk areas of any maintenance visit. Most incidents happen when a door opens unexpectedly, when a restraining device fails, or when an engineer’s attention is elsewhere and a door is left accessible to others. Because the risks tend to build from small oversights rather than dramatic failures, a methodical approach to every landing door is essential.
Unintended opening from safety edges and sight guards
Where safety edges or sight guards are fitted, there’s a risk that opening the car doors mid-shaft causes the landing pick-up rollers to catch and inadvertently unlatch a landing door below the floor being worked on. If this happens, the door can open into the shaft with nothing in place to stop someone stepping through it.
Before starting work, engineers should open the car door around 50mm to check for any engagement with the landing rollers below. If this can’t be done safely, the issue should be reported to the line manager. A landing barrier should also be placed on the working floor and the floor below, and a second engineer positioned on the lower floor for the duration of the task.
Restraining and stopping devices
Holding a landing door open isn’t inherently dangerous, but using the wrong device to do it can be. Improvised methods, such as wedging a screwdriver under a hanging roller, carry a real risk of the door self-releasing and the tool dropping into the shaft or onto whoever is below.
Only company-approved door blocking devices should be used to hold a landing door open, and once fitted, engineers should give the door a firm pull to confirm it’s secure. A landing barrier should always be placed at the entrance while the door is restrained, and the opening should never be left unattended, since anyone unaware of the works could attempt to use the lift.
Controlling access to the shaft
Beyond the door mechanism itself, access control around an open landing entrance deserves the same level of care. Unlocking triangle or release keys should never be left in a door or handed to anyone outside the engineering team, and any opening should have a barrier and be clearly signed for the full duration it’s exposed, not just while an engineer is actively working on it.
Where the public or building occupants are nearby, a brief word to site staff or a visible notice can prevent someone assuming the lift is simply out of service and trying to pass through.
Checking interlocks before leaving site
Before closing up, engineers should confirm the landing door interlock is engaged and the door is fully secure, rather than relying on it appearing closed. A quick pull test on every door disturbed during the visit takes seconds and catches faults that a visual check alone can miss, particularly on older or worn mechanisms.
Building good habits on site
As with most shaft-related risks, good outcomes come down to consistency: treating every landing door as though it could open unexpectedly, using the correct equipment rather than an available substitute, and never leaving an open entrance without a barrier or unattended, even briefly. These habits cost very little time but make a significant difference to safety on site.
For more lift safety guidance and industry updates, keep following our lift safety blog series. You can also take a Toolbox Talk on landing doors via our sister company here.
Don’t forget to follow us on LinkedIn.